Features:
- browser interface provides remote connectivity to monitor the GC system, check system logs, and perform diagnostic tests both inside and outside the laboratory, provides access to most of the GC touchscreen functions, plus Help functions, without having to be near the instrument:
- gaining access from any browser (tablet, laptop or PC);
- editing GC methods and sequences without the need for a data acquisition and processing system;
- calling the menu items "Diagnostics", "Maintenance", "Logs" and "Help";
- viewing magazines and referring to the user manual without leaving the table;
- check equipment status and perform diagnostics from anywhere within a secure lab network;
- full-featured touchscreen provides a visual report of system configuration, allowing method and sequence updates, maintenance procedures, and instrument health checks;
- Built-in intelligence autonomously monitors system health, alerts the user to potential problems before they affect chromatographic performance, and offers helpful step-by-step troubleshooting steps;
- Unique 6th Generation Microchannel EPC architecture significantly improves reliability and durability against gaseous contaminants such as particulate matter, water and oil, extending instrument consumable life
- Capillary Flow (CFT) technology provides unique gas flow connections for Multidimensional Gas Chromatography (GC x GC / Deans Switch), Integrated Two-Dimensional Gas Chromatography (GC x GC) with flow modulation and backwash at the beginning, middle or end of the analytical column that is mounted into a furnace and has a very low thermal mass;
- a single-strand TCD that does not require a separate reference gas or manual potentiometer setting, but provides a stable baseline with minimal signal drift typically seen when switching a valve;
- automatic FID ranging provides detection and quantification from percentage levels to parts per billion (ppb) in a single shot;
- Compatible with all GC / MS platforms
- Sulfur or nitrogen chemiluminescence detector provides low ppb, equimolar response and quantification of sulfur or nitrogen impurities without quenching from the matrix;
- cost-effective state-of-the-art electronic pneumatic controllers such as helium storage module, hydrogen sensors and alternative carrier gas solutions significantly reduce the amount of helium used, providing flexibility and increasing safety in your laboratory;
- Additional Smart ID keys included with GC columns provide information such as using the column with default parameters for configuration to help automate method setup;
- Expanded configurability with the ability to install and operate up to two evaporators and four detectors simultaneously, includes six GC column smart IDs, and three USB ports.
- High-tech detector electronics and full range of digital data paths quantify peaks across the entire dynamic range of the detector (107 for FID) in a single analysis;
- EPC is provided for evaporators and detectors, control range and resolution are optimized for a specific evaporator or detector module, up to eight EPC modules can be installed, due to which 19 EPC channels are controlled;
- column oven with dimensions, cm - 28 x 31 x 16;
- Column capacity per oven - Up to two 105 m capillary columns with 0.530 mm ID or two 10 'glass packed columns (9' 'loop diameter, 1/4' 'OD) or two 20' stainless steel packed columns (outer 1/8 inch diameter);
- operating temperature range, С - ambient temperature from +4 to 450; with cryogenic cooling with liquid N2 - -80–450; cryogenic cooled CO? - -40-450;
- resolution of the set temperature value, 0 ° C - 0.1;
- supports 20 temperature changes with 21 isotherms, negative temperature changes are allowed;
- maximum achievable heating rate 0 ° C / min - 120 (120V appliances are limited to 75 ° C / min);
- furnace cooling - from 450 to 500 ° C - 4 minutes;
- maximum analysis time, min - 999.99;
- Types of evaporators (a maximum of two can be installed) - Packed column evaporator (PPIP), split / splitless capillary column evaporators in standard and inert design (S / SL), universal multi-mode evaporator (MMI), temperature programmable evaporator and direct on-column injection (PCOC), programmable temperature evaporator (PTV), volatile compound inlet (VI);
- Electronic pressure regulator (EPC) provides standard corrections for changes in barometric pressure and ambient temperature;
- Pressure is controlled to 0.001 psi over the 0 to 150 psi range, and the pressure setpoint gain can be set to 0.001 for the 0.000 to 99.999 psi range and 0.01 psi for the 100.00 to 150.00 psi range;
- the ability to select the unit of measurement of pressure: psi, kPa or bar;
- selectable makeup gas and additional gas settings for He, H2, N2 and argon / methane;
- dimensions W x D x H, mm - 580 x 510 x 490;
- weight, kg - 49.